Applications · Materials supply

Microcement Bathrooms in Ireland

Specify bathroom walls, floors and wet zones separately. The continuous appearance comes from coordinated materials, not from using a wall finish on a floor or treating a sealer as shower tanking.

Different bathroom surfaces, different finishing choices

Microfinishing is for bathroom walls; Microtraffic is the cement-based floor finish. Micronoslip provides the documented Class 3 slip-resistant texture for shower trays and wet-area floors. The finish should follow the use of the surface, even where the colour continues from one part of the room to another. Microfinishing must not be specified on the surrounding bathroom floor.

The cement-based systems share 40 standard colours. Pure Lime offers a separate 33-colour palette and its own build-up. Choose the system before selecting the colour, and look at physical standard samples in the bathroom before committing. The absence of grout lines creates visual continuity, but preparation, waterproofing and the protective finish remain separate practical decisions.

Build-up from prepared substrate to sealed finish

For standard cement-based wall and floor areas, prepare the substrate, apply the specified KC Primer, then Microbase. Walls and floors use three base coats, maximum 1 mm per coat, with 50 g fibreglass mesh embedded in the fresh base coat and mandatory on floors. Follow with two finishing coats: Microfinishing for walls or Microtraffic for floors. Complete the standard finish with two-component PU Varnish.

Micronoslip is applied directly in three coats, without Microbase, with mesh essential on floors. Its documented consumption is 3.0 kg/m² for the three coats. Do not carry the standard Microbase sequence into a Micronoslip area simply because the surfaces are adjacent. The application guide and technical data sheets should be read with the project specification.

Showers and wet rooms: tanking beneath the finish

Standard microcement is water-resistant once sealed; it is not waterproof. Showers and wet rooms require SubVap tanking beneath the microcement. SubVap is a two-component waterproofing mortar. Its role is different from that of the final varnish, so the sealed appearance of a shower cannot be used as evidence that tanking is unnecessary.

Send the substrate details and photographs of the planned wet zones with your specification request. Identify the shower floor, walls and any adjoining coated areas rather than describing everything as one bathroom surface. The choice of texture, the waterproofing build-up and the coating sequence should be settled before ordering. KCBerry supplies and specifies the materials; application and detailing are carried out by you or your appointed contractor.

Over tiles: preparation still comes first

Sound, firmly bonded existing tiles can remain beneath the documented system. Clean and degrease the substrate, repair defects and prepare glossy surfaces as directed before priming. Loose tiles, cracking or damp conditions need to be addressed, not hidden beneath a thin decorative coating. The same principle applies to plaster, screed or concrete: the substrate must be suitable for the chosen build-up.

For a renovation decision, compare the Irish bathroom microcement and tiles guide with the broader microcement versus tiles article. If you are considering a lime-based appearance, read microcement versus tadelakt. Those comparisons help distinguish visual preference from the preparation and protection that the room requires.

Measure walls, floor and shower areas

Multiply wall width by height, and floor length by width, in metres. Add the areas receiving the same finish and keep wet zones identified separately. Include coated reveals, niches and returns rather than using only the floor area as the bathroom total. A measured list of surfaces is more useful for a specification than the room footprint alone.

Microbase uses ≈2.0 kg/m² in total for the 3 coats — one 20 kg bucket per 10 m² on walls and floors, with mesh mandatory on floors. Microfinishing uses 0.5 kg/m² for two coats on walls only; Microtraffic uses 0.95 kg/m² for two coats. Micronoslip uses 3.0 kg/m² for three direct coats. Use the calculator and kits to compare full-cover quantities, then confirm the wet-area specification. Read the bathroom materials cost guide and bathroom ideas article for related planning.

Care of a sealed bathroom

Use a soft cloth and a mild, neutral cleaner, avoiding abrasives and aggressive chemicals. The sealer protects the surface and its condition should be maintained. Floors benefit from a periodic sealer refresh according to wear; a seamless bathroom is not a maintenance-free claim. Follow the curing and use instructions for the specified products instead of assuming the room can be used as soon as the last coat appears dry.

Questions before you order

Is microcement waterproof in a bathroom?
Standard microcement is water-resistant once sealed. Showers and wet rooms require SubVap tanking beneath the finish.
Which finish belongs on a bathroom floor?
Microtraffic is the standard cement-based floor finish. Micronoslip is specified for shower trays and wet-area floors; Microfinishing is for walls only.
Does Micronoslip go over Microbase?
No. Micronoslip is applied directly in three coats without Microbase, with mesh essential on floors.
Can bathroom tiles stay in place?
Yes, if sound and well bonded, with the specified preparation. Loose or defective substrates must be repaired first.
Does KCBerry fit the bathroom finish?
No. KCBerry supplies, sizes and specifies the materials. You or your contractor applies the system.

What a microcement bathroom costs

Measure all coated walls and floors rather than the room footprint alone: a 20 m² Complete Kit costs €867.15, and a 30 m² kit costs €1,219.00, including 23% VAT. These are supply-only material prices; preparation, wet-zone tanking and independent application are separate considerations. Read the Ireland microcement bathroom cost guide for the full budget breakdown.

Showers and wet rooms: specify the waterproofing

Standard microcement — sometimes written micro cement — is water-resistant once sealed, not waterproof. Showers and wet rooms require the two-part SubVap waterproof tanking system beneath the finish, with the surface finish and drainage specified for the wet zone. Our microcement shower and wet-room guide explains tanking, sealing and Micronoslip; KCBerry supplies the materials, not the application.