Specify each hospitality surface separately
Use Microfinishing for decorative walls and Microtraffic for trafficked floors. In bathroom shower and wet-room areas, specify Micronoslip where the textured finish is required, together with SubVap tanking beneath the microcement. A continuous colour scheme does not justify applying a wall finish to a corridor floor or removing wet-zone waterproofing.
The cement-based systems share 40 standard colours; Pure Lime has a separate 33-colour palette. Choose the product for the surface before choosing a shade. For the wider interior specification, read the commercial microcement guide, and use the colours page to distinguish the standard and PURE ranges.
Documented wall, floor and wet-zone build-ups
For standard cement-based surfaces, prepare the substrate and use the specified KC Primer, followed by Microbase. Apply three base coats on walls and floors, maximum 1 mm per coat, with 50 g fibreglass mesh embedded in the fresh base coat and mandatory on floors. Add two coats of Microfinishing on walls or Microtraffic on floors, then the specified PU Varnish.
Micronoslip is applied directly in three coats without Microbase, with mesh essential on floors. SubVap provides tanking beneath shower and wet-room microcement. The standard sealed finish is water-resistant, not waterproof. Use the technical data sheets and application guide to keep the sequences distinct when different surfaces meet in one room.
Measure the project by room and surface
Measure wall width and height and floor length and width in metres. Include coated reveals, returns and other details. Group areas by system rather than using the number of rooms as a materials quantity. Identify wet zones separately so the tanking and direct Micronoslip sequence are not lost inside a general bathroom total.
Microbase uses ≈2.0 kg/m² in total for the 3 coats — one 20 kg bucket per 10 m² on walls and floors, with mesh mandatory on floors. Microfinishing uses 0.5 kg/m² for two wall coats, Microtraffic 0.95 kg/m² for two floor coats, and Micronoslip 3.0 kg/m² for three direct coats. Use the calculator to compare kit coverage, then request a specification for the recorded areas and substrate details.
Prepare, protect and maintain the surface
Sound existing tiles, screed, plaster or concrete can receive the documented preparation. Loose material, cracks, moisture problems and movement joints need assessment before coating. Clean and degrease the substrate and follow the product method; a decorative finish is not a repair for unstable construction. Send photographs if the existing surface condition is uncertain.
Clean the sealed surface with a mild, neutral cleaner and avoid abrasive tools or aggressive chemicals. Floors benefit from a periodic sealer refresh according to wear. Follow curing instructions before use rather than promising a guest-room turnaround. Read the bathroom specification guide for wet areas. KCBerry supplies and specifies the materials; it does not install finishes, manage refurbishment or provide a hotel fit-out service.